LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q02UCPU Strctured Programming Manual (Application Functions) PDF

MITSUBISHI Q02UCPU Strctured Programming Manual (Application Functions) PDF

Brand: MITSUBISHI
Product model: Q02UCPU
Name: CPU
Sort: Strctured Programming Manual (Application Functions)
File language: English
File size: 5.50MB
Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
No heater disconnection detection function.
Sampling period: 0.5s/4 channel Q02UCPU PDF.
18 point terminal station.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling Q02UCPU
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode Q02UCPU PDF.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the ppeak current, which is helpful for saving energy and reducing the operation cost Q02UCPU PDF Q02UCPU Manual.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process MITSUBISHI Strctured Programming Manual.
Automatic adjustment of cost (time, material and electrical energy) can be reduced. MODBUS/TCP Master slave station.
10BASE-T/100BASE-TX.
MODBUS interface module capable of connecting MODBUS compatible device such as temperature regulator, measuring device and so on MITSUBISHI Strctured Programming Manual.
Support MODBUS communication function, and can be compatible with the third party MODBUS to communicate from various station equipment.
Support MODBUS communication functions from the station, can communicate with the third party programmable controller MODBUS master device.
Through the linkage function, the master can be connected to the CH1 side (RS-232),
And through the QJ71MB91 and connected to the CH2 side (RS-422/485) of a number of stations for communication MITSUBISHI Strctured Programming Manual Q02UCPU Strctured Programming Manual.
The RS-232 interface (1 credit on the 1 pass) MODBUS master device withh multiple MODBUS communication from the station equipment Q02UCPU Manual. (only QJ71MB91)
Master / slave station functions can be used simultaneously. (only QJ71MT91)
Related products
MITSUBISHI
CPU unit
A1SJCPU
MITSUBISHI CPU unit A1SJCPU
Program memory capacity: 8k. Input / output p
MITSUBISHI
Sports CPU module (old model)
Q172CPU
MITSUBISHI Sports CPU module (old model) Q172CPU
Control axis: maximum 32 axes. Compact size a
MITSUBISHI
High performance CPU
Q25HCPU
MITSUBISHI High performance CPU Q25HCPU
Program capacity: 252 K step. Input / output