GI-50/125 optical cable.
Double ring.
Remote I/O net (remote master station).
MELSECNET/H network module capable of composing large scale flexible network system Q03UDCPU PDF.
The MELSECNET/H network system includes the PLC network of the control station and the communication between the stations and the remote I/O network in the remote station remote I/O station.
Optical fiber loop system...... High speed communication of 10Mbps/25Mbps is realized
Q03UDCPU
The distance between stations, the length of the total cable length, strong anti-interference.
Coaxial bus system...... Using low cost coaxial cable, the network construction cost is lower than that of the optical fiber loop network Q03UDCPU PDF.
Twisted pair bus system...... Combined with high performance price ratio network module and twisted pair cable,
The construction cost of network system is very low.Application: extension.
Suitable for safety standards: EN954-1 class 4, PLe ISO13849-1 Q03UDCPU PDF.
Security input points: 1.
Use special setting monitoring tools to configure the configuration directly.
Constitute a rich set of components can be easily and quickly set the hardware structure.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic MITSUBISHI Programming Manual .
Logical import and export.
You can store the connection settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file Q03UDCPU Manual. Input voltage range: AC100-240V.
Output voltage: DC5V.
Output power: 8 MITSUBISHI Programming Manual . 5A.
Simplified program debugging.
Can use the software with the implementation of the conditions of the test function, any step in the program,
Changes the value of the soft component to a user specified value.
In the past, when debugging the specific loop process, the need to add a set of soft components of the program,
At present, through the use of the function, no need to change the program, you can make a specific loop program segment execution action MITSUBISHI Programming Manual .
Therefore, do not need to change the program separately in order to debug, debugging operation is more simple.
Through the expansion of soft components, more convenient to create the program.
M soft components and B soft components can be expanded to 60K points, making the program easier to understand.
Auto backup key data.
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameters due to forgetting to replace the battery Q03UDCPU Programming Manual .
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and oother planned downtime,
The data is lost due to battery depletion Q03UDCPU Manual.
The next time the power is turned on, the backup data will be automatically restored.