LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q03UDCPU Strctured Programming Manual (Common Instructions) PDF

MITSUBISHI Q03UDCPU Strctured Programming Manual (Common Instructions) PDF

Brand: MITSUBISHI
Product model: Q03UDCPU
Name: CPU
Sort: Strctured Programming Manual (Common Instructions)
File language: English
File size: 18.43MB
SRAM+E2PROM memory card.
RAM capacity: 512KB.
E2PROM capacity: 512KB. Module connector 1Ch.
1ch RS-232.
The possibility of expanding control with intelligent function Q03UDCPU PDF.
Providing a variety of analog modules, is the ideal choice for process control applications.
Can also meet the needs of high speed, high precision control.
Most suitable analog modules for high speed conversion control Q03UDCPU
Can provide a variety of analog and digital analog conversion module products.
These modules have a variety of functions, in the connection of equipment, to achieve the greatest flexibility.
Can meet the inverter control, such as high-speed conversion needs Q03UDCPU PDF.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings. And there is no need to select the cable, the straight line and the cross line can be used Q03UDCPU PDF.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.The telephone line of the interface module is connected with the peripheral equipment.Redundant CPU data tracking cable length of 3 meters MITSUBISHI Strctured Programming Manual.
Can only be used for MITSUBISHI Q series PLC redundancy CPU.8 channels.
Input: AC0~5A AC0~50A, CT, AC0~100 until AC0~600A.
Output: 0~10000.
18 point terminal.
Directly connected to the CT sensor, saving wiring and space of the CT innput module Q03UDCPU Manual.
Directly connected with CT sensor and programmable controller,
No need for external connection signal converter, etc MITSUBISHI Strctured Programming Manual. .
Very accurate measurement results can be obtained by stable data transfer speed,
Then, load control and operation of the system and equipment are carried out, and the power supply system is managed and monitored MITSUBISHI Strctured Programming Manual.
Directly connect the CT sensor, saving wiring and space
In the case of no external signal converter, directly connected to the CT sensor.
A module can be used to measure up to 8 channels of alternating current, thereby reducing wiring time and cost.
Set the CT sensor type (input range) for each channel.
Through a module to select from AC0 ~ 5A to 600A ~ CT AC0 sensor.
Preventive maintenance can be carried out by detecting the peak current.
Peak current detection function
By detecting the peak current, the equipment can perform maintenance and troubleshooting.
Take the motor as an example, the load applied on the motor changes due to wear and damage of the gear,
Load current will sudddenly change Q03UDCPU Strctured Programming Manual.
By detecting the transient peak current at this time, the fault of the equipment can be diagnosed.
Input signal error detection function
Can detect whether the CT input value is out of range (higher than the peak value)) Q03UDCPU Manual.
Because the large current flow on the measurement object is beyond the range limit,
Therefore, the error of the measurement object can be monitored.
Related products
MITSUBISHI
With Ethernet CPU
Q03UDECPU
MITSUBISHI With Ethernet CPU Q03UDECPU
Input / output points: 4096 points. Numer of
MITSUBISHI
General high speed CPU
Q03UDVCPU
MITSUBISHI General high speed CPU Q03UDVCPU
Input / output points: 4096 points. Input / o
MITSUBISHI
General purpose CPU
Q03UDCPU
MITSUBISHI General purpose CPU Q03UDCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
Motion CPU module
Q173DCPU
MITSUBISHI Motion CPU module Q173DCPU
Control axis: maximum 32 axes. Manual pulse g