Output: 2 channels.
Input (resolution): 0~12000; -12000~12000; 0~12000; -16000~16000.
Output DC0~20mA; DC-12~12V.
Conversion speed: 10ms/1 channel.
18 point terminal station Q04UDVCPU PDF.
Isolation between channels.
The possibility of expanding control with intelligent function.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark
Q04UDVCPU
Provide support for process control using a general purpose programmable controller.
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output Q04UDVCPU PDF.
Hardware and installation costs have been greatly reduced due to the need for an external isolation amplifier.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input module Q04UDVCPU PDF.
No external isolation amplifier required.
Without the use of inter channel isolation analog modules.
Using the inter channel isolation analog module. SRAM+E2PROM memory card.
RAM capacity: 256KB.
E2PROM capacity: 256KB. Express PCI bus.
Support Japanese, English OS.
Master / local station sharing MITSUBISHI Programming Manual.
Support Ver.2 CC-Link version.
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 1556kbps Q04UDVCPU Manual.
CC-Link/LT from the station does not need any parameter settings MITSUBISHI Programming Manual.
Only need to set up the transmission speed in the master module, you can use the remote I/O.
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information) MITSUBISHI Programming Manual.
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmission) communication separately, so as to ensure the timeliness of.
Even if the information reaches saturation, it will not affect the link scan time.
Make the mixed data environment intelligent, to achieve a new manufacturing system IE CC-Link field network module.
Using Ethernet cables and connectors available on the market to reduce costs.
High speed communication capable of communicating with 1Gbps.
Improve the communication response, significantly shorten the cycle time.
Improve the performance of cycle data update. Reduces the transsmission delay time and the application of the synchronization waiting time Q04UDVCPU Programming Manual.
Data can be read or written to other station programmable controller.
Status of IE CC-Link field network can be confirmed by Works2 GX.
Can be in the Workss2 GX up and down the abnormal position, the cause of the exception, the event record,
So it can reduce the time of abnormal to resume normal operation Q04UDVCPU Manual.