Input: DC4~20mA (connecting two wire transmitter); DC0~20mA.
Output (resolution): 0~4000. 0~12000.
Conversion speed: 10ms/ channel.
40 pin connector Q06HCPU-A PDF.
Isolation between channels.
Power supply to a two wire transmitter.
The possibility of expanding control with intelligent function.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark
Q06HCPU-A
Provide support for process control using a general purpose programmable controller.
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output Q06HCPU-A PDF.
Hardware and installation costs have been greatly reduced due to the need for an external isolation amplifier.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input module Q06HCPU-A PDF.
No external isolation amplifier required.
Without the use of inter channel isolation analog modules.
Using the inter channel isolation analog module.8 channels.
Thermocouple (B, R, S, K, E, J, T, N)
Shedding detection function.
Conversion speed: 640ms/8 channel.
Inter channnel isolation MITSUBISHI Strctured Programming Manual Q06HCPU-A Manual.
40 pin connector.
Most suitable for process control of isolated analog modules.
Temperature data can be collected by connecting thermocouple / thermal resistance.
Products can choose multi-channel (8 channel) input type and channel isolation type.
Customers can choose the most suitable model according to the intended use MITSUBISHI Strctured Programming Manual.
Auto backup key data
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameters due to forgetting to replace the battery.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and other planned downtime,
The data is lost due to battery depletion MITSUBISHI Strctured Programming Manual.
The next time the power is turned on, the backup data will be automatically restored.
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc Q06HCPU-A Strctured Programming Manual. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage ccard in advance Q06HCPU-A Manual.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown.