Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
Heater disconnection detection function.
Sampling period: 0.5s/4 channel Q06PHCPU PDF.
18 point terminal table x2.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling
Q06PHCPU
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode Q06PHCPU PDF.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost Q06PHCPU PDF.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process MITSUBISHI Programming Manual.
Automatic adjustment of cost (time, material and electrical eenergy) can be reduced Q06PHCPU Manual. Input: 2 channels.
10kpps.
Counter input signal: DC5/12/24V.
External input: DC5/12/24V.
Uniform output: Transistor (drain type).
Used to replace the A series of large modules "AD61-S1" MITSUBISHI Programming Manual.
40 pin connector.
Support high resolution devices. Pulse input and high speed counter module product group satisfying high speed and high precision control application.
High speed counter module for counting high-speed pulse train.
Can be used in combination with the external encoder for positioning and other control MITSUBISHI Programming Manual.
The maximum count rate can be switched, and the low frequency pulse is counted from the high speed pulse to the rising edge / falling edge.
Each 1 channel is equipped with 2 points of external uniform output.
Can be selected according to the use of "consistent output function", "continuous comparison function", to achieve high-speed control of external equipment. (QD64D2)
Provides a variety of functions, such as the same output test function (using a continuous comparison function), the default function, the latch counteer function,
In order to meet the needs of various applications Q06PHCPU Programming Manual. (QD64D2)
The maximum count rate of the input pulse can be up to 8Mpps (differential input, 2 phase, 4 double frequency).
Can be in the semiconductor, liquid crystal mannufacturing and other high position accuracy requirements of the equipment,
Perform accurate position tracking using high resolution encoders Q06PHCPU Manual. (QD65PD2)