LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q10UDHCPU Programming Manual (MELSAP-L) PDF

MITSUBISHI Q10UDHCPU Programming Manual (MELSAP-L) PDF

Brand: MITSUBISHI
Product model: Q10UDHCPU
Name: PLC
Sort: Programming Manual (MELSAP-L)
File language: English
File size: 3.16MB
Program capacity: 8K step.
Input / output points: 1024 points.
Number of input and output elements: 2048.
Continue to go beyond, to climb the peak of Q series Q10UDHCPU PDF.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users Q10UDHCPU
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights Q10UDHCPU PDF.
CPU module expansion standard RAM (max 8MB).
Can be used with the SD memory card at the same time.
Continuous access file register.8 channel.
Input: DC-10~10mA; 0~20mA.
Output (resolution): 0~4000; -4000~4000; 0~12000; -12000~12000; 0~16000; -16000~16000.
Conversion speed: 10ms/ channel Q10UDHCPU PDF.
40 pin connector.
Isolation between channels.
The possibility of expanding control with intelligent function.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark.
Provide support for process control using a general purpose programmable controller MITSUBISHI Programming Manual.
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output.
Hardware and installation costs have been greatly reduced due to the need for an external isolation amplifier MITSUBISHI Programming Manual.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input module.
No external isolation amplifier required.
Without the use of inteer channel isolation analog modules Q10UDHCPU Manual.
Using the inter channel isolation analog module MITSUBISHI Programming Manual. PCI bus /PCI-X bus.
Support Japanese, English OS.
Multimode fiber optic cable.
Dual loop controller network (control station / common station).
DB A20 AnyWire system uses a separate transmission mode,
Sensor networks to achieve high speed and high reliability.
The transmission distance of 50m/200m/1km/3km can be selected.
1 modules can be up to 512 points of the input, 512 points of output (standard setting).
Even branch wiring, but also to detect transmission lines.
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings.
Only need to set up the transmission speed in the master module, you can use the remote I/O.
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able tto transmit large number of bits data (such as ON/OFF information) and word data (such as analog information) Q10UDHCPU Programming Manual.
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmmission) communication separately, so as to ensure the timeliness of Q10UDHCPU Manual.
Even if the information reaches saturation, it will not affect the link scan time.
Related products
MITSUBISHI
CPU component
A2SHCPU
MITSUBISHI CPU component A2SHCPU
I/O control method: refresh mode or direct mo
MITSUBISHI
CPU component
A1SHCPU
MITSUBISHI CPU component A1SHCPU
I/O control method: refresh mode or direct mo
MITSUBISHI
Process CPU
Q25PRHCPU
MITSUBISHI Process CPU Q25PRHCPU
Program capacity: 252 K step. Input / output