Control axis: maximum 8 axes.
Teaching operation function: No.
To stop the speed control function at the specified location.
The servo motor can rotate at a predetermined speed,
After starting the specified location to stop the instruction,
Can be set in advance to stop the location Q12HCPU PDF.
You can change the speed by changing the value of the options at the time of the operation,
You can also change the acceleration / deceleration time
Q12HCPU
Phase compensation function.
The mixed function of virtual mode and real mode.
Smooth clutch linear acceleration / deceleration function.PCI bus.
Support Japanese, English OS Q12HCPU PDF.
GI optical cable.
Dual loop controller network (control station / common station).
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information) Q12HCPU PDF.
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmission) communiication separately, so as to ensure the timeliness of Q12HCPU Manual.
Even if the information reaches saturation, it will not affect the link scan time.
DB A20 AnyWire system uses a separate transmission mode,
Sensor networks to achieve high speed and high reliability MITSUBISHI User's Manual.
The transmission distance of 50m/200m/1km/3km can be selected.
1 modules can be up to 512 points of the input, 512 points of output (standard setting).
Even branch wiring, but also to detect transmission lines MITSUBISHI User's Manual. MES interface module.
Need MX MESInterface software and CF card.
Easily connect production equipment and information system.
Through the excellent database sharing function, greatly reduce the cost of information.
By direct connection, the connection process of the enterprise system database (such as MES) is simplified MITSUBISHI User's Manual.
Module configuration is simple, without any programming.
The data can be monitored in the module side, when a user defined trigger condition occurs,
Will be read in the form of SQL text and send the specified data to the MES.
The network load can be redduced compared with the previous scheme which is based on the gateway PC to obtain / monitor the data Q12HCPU User's Manual.
Receive information from the MES, perform pre stored SQL tasks.
In addition, the production instructions from the MES are also receeived,
The production information can be downloaded from the database, and the modification of the formula information can be conveniently carried out Q12HCPU Manual.