Input / output points: 4096 points.
Size side mode: small end mode.
SD memory card: available.
Q24DHCCPU-LS without OS.
C language controller is a long term stable supply, high reliability, high performance, flexible MELSEC on the implementation of the C language program revolutionary open platform Q12PHCPU PDF.
Including pre installed VxWorks,
This C language controller can be used with various modules of the MELSEC-Q series,
Partner products and open source,
Client program assets, such as portfolio use to build a variety of systems
Q12PHCPU
As can be used in all scenarios, can replace the computer, a new computer platform,
C MELSEC language controller stronger, simpler, higher performance, more flexible, in the future will also continue to continue to develop Q12PHCPU PDF.
Program capacity: 124 K step.
Input / output points: 4096 points.
Number of input and output elements: 8192.
Processing speed: 0.034 s.
Program memory capacity: 496 KB Q12PHCPU PDF.
Support USB and RS232.
CPU module expansion standard RAM (max 8MB).
Can be used with the SD memory card at the same time.
Continuous access file register.
Ultra high speed processing, production time is shortened, better performance.
As applications become larger and more complex, it is necessary to shorten the system operation cycle time MITSUBISHI Strctured Programming Manuual Q12PHCPU Manual.
The operation period can be shortened by the super high basic operation speed 1.9ns.
In addition to achieve in the past with the control of single-chip high-speed control,
The system performance can be improved by reducing the total scan time,
To prevent any possible performance bias MITSUBISHI Strctured Programming Manual. The input and output module installation number: 4.
Could extend the connection: not to extend the connection.
Application module: QS series module.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system MITSUBISHI Strctured Programming Manual.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outsiide the standard control procedures Q12PHCPU Strctured Programming Manual.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memory,,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down Q12PHCPU Manual. "