LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q12PHCPU Strctured Programming Manual (Application Functions) PDF

MITSUBISHI Q12PHCPU Strctured Programming Manual (Application Functions) PDF

Brand: MITSUBISHI
Product model: Q12PHCPU
Name: CPU
Sort: Strctured Programming Manual (Application Functions)
File language: English
File size: 5.50MB
Input: 2 channels.
200/100/10kpps.
Counter input signal: DC5/12/24V.
External input: DC5/12/24V.
Uniform output: Transistor (drain type).
DC12/24V.
0.1A/ point Q12PHCPU PDF.
0.4A/ common end.
40 pin connector.
Support high resolution devices. Pulse input and high speed counter module product group satisfying high speed and high precision control application.
High speed counter module for counting high-speed pulse train Q12PHCPU
Can be used in combination with the external encoder for positioning and other control.
The maximum count rate can be switched, and the low frequency pulse is counted from the high speed pulse to the rising edge / falling edge Q12PHCPU PDF.
Each 1 channel is equipped with 2 points of external uniform output.
Can be selected according to the use of "consistent output function", "continuous comparison function", to achieve high-speed control of external equipment. (QD64D2)
Provides a variety of functions, such as the same output test function (using a continuous comparison function), the default function, the latch counter function,
In order to meet the needs of various applications Q12PHCPU PDF. (QD64D2)
The maximum count rate of the input pulse can be up to 8Mpps (differential input, 2 phase, 4 double frequency).
Can be in the semiconductor, liquid crystal manufacturing and other high position accuracy requirements of the equipment,
Perform accurate position tracking using high resolution encoders MITSUBISHI Strctured Programming Manual. (QD65PD2)Output: 8 channels.
Input (resolution): 0~4000; -4000~4000; 0~12000; -12000~12000; -16000~16000.
Output: DC-10~10V MITSUBISHI Strctured Programming Manual.
Conversion speed: 80 s/1 channel.
18 poinnt terminal station Q12PHCPU Manual.
No external isolation amplifier required.
Without the use of inter channel isolation analog modules.
Using the inter channel isolation analog module.
The possibility of expanding control with intelligent function.
Providing a variety of analog modules, is the ideal choice for process control applications MITSUBISHI Strctured Programming Manual.
Can also meet the needs of high speed, high precision control.
Most suitable analog modules for high speed conversion control.
Can provide a variety of analog and digital analog conversion module products.
These modules have a variety of functions, in the connection of equipment, to achieve the greatest flexibility.
Can meet the inverter control, such as high-speed conversion needs.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-preecision control of the positioning of the industry, the control needs of various fields Q12PHCPU Strctured Programming Manual.
Can also be used in combination with the CPU module to achieve appropriate control.
Transformer isolation between power supply and output.
High insulation strength Q12PHCPU Manual.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input module.
Related products
MITSUBISHI
With Ethernet CPU
Q04UDEHCPU
MITSUBISHI With Ethernet CPU Q04UDEHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
CPU unit
A0J2HCPU
MITSUBISHI CPU unit A0J2HCPU
Input and output points: 480 points. Input /
MITSUBISHI
With Ethernet CPU
Q10UDEHCPU
MITSUBISHI With Ethernet CPU Q10UDEHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
High performance CPU
Q06HCPU
MITSUBISHI High performance CPU Q06HCPU
Program capacity: 60 K step. Input / output p