SRAM+E2PROM memory card.
RAM capacity: 32KB.
E2PROM capacity: 32KB. Input voltage range: AC100-240V.
Output voltage: DC5V.
Output power: 8.5A.
Simplified program debugging Q13UDHCPU PDF.
Can use the software with the implementation of the conditions of the test function, any step in the program,
Changes the value of the soft component to a user specified value.
In the past, when debugging the specific loop process, the need to add a set of soft components of the program,
At present, through the use of the function, no need to change the program, you can make a specific loop program segment execution action Q13UDHCPU PDF
Q13UDHCPU
Therefore, do not need to change the program separately in order to debug, debugging operation is more simple.
Through the expansion of soft components, more convenient to create the program.
M soft components and B soft components can be expanded to 60K points, making the program easier to understand Q13UDHCPU PDF.
Auto backup key data.
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameters due to forgetting to replace the battery Q13UDHCPU Manual.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and other planned downtime,
The data is lost due to battery depletion MITSUBISHI Programming Manual.
The next time the power is turned on, the backup data will be automatically restored.Input points: servo external signal 32 points, 8 axis.
Input mode: source / drain type MITSUBISHI Programming Manual.
Input and output points: 32 points.
Better user experience data recording function.
Easy to record, no need to program.
Simply through the special configuration tool wizard to easily complete the settings,
The collected data can be saved in CSV format to SD storage card MITSUBISHI Programming Manual.
Can be effectively used to save the CSV file to facilitate the creation of a variety of reference materials,
Including daily reports, generate reports annd general reports Q13UDHCPU Programming Manual.
These data can be applied to the data analysis, tracing, etc..
To record the change of control data without missing.
Data can be collected in a time interval or in a millisecond time interval,
To record the changge of the specified control data without any omission Q13UDHCPU Manual.
Therefore, in the event of failure, can quickly determine the cause, the precise action analysis.