MODBUS RTU/MODBUS ASCII Master slave station.
RS-232.
RS-422/485.
MODBUS interface module capable of connecting MODBUS compatible device such as temperature regulator, measuring device and so on Q172HCPU PDF.
Support MODBUS communication function, and can be compatible with the third party MODBUS to communicate from various station equipment.
Support MODBUS communication functions from the station, can communicate with the third party programmable controller MODBUS master device
Q172HCPU
Through the linkage function, the master can be connected to the CH1 side (RS-232),
And through the QJ71MB91 and connected to the CH2 side (RS-422/485) of a number of stations for communication Q172HCPU PDF.
The RS-232 interface (1 credit on the 1 pass) MODBUS master device with multiple MODBUS communication from the station equipment. (only QJ71MB91)
Master / slave station functions can be used simultaneously. (only QJ71MT91)FL-net (OPCN-2) Ver Q172HCPU PDF. 1.00 interface.
10BASE5/10BASE-T use.
Optimal network matching for application purposes and applications,
Seamless communication between different hierarchical systems.
Enhancing the ability of information communication through network.
This is also a major task in the field of automation.
Network environment provided by Q series
Is truly open & seamless MITSUBISHI Programming Manual.
Including based on universal ethernet,
Achieve easy management of the environment "IE Control CC-Link" controller network,
As well as in its managemment to achieve a high-speed, high-capacity transmission of the "IE Field CC-Link" field network MITSUBISHI Programming Manual Q172HCPU Manual.
Also including Japan''s first, to achieve the world standard,
And get the SEMI certification of the field network "CC-Link",
And inherited the design concept of the provincial distribution network CC-Link/LT".
And support sensor networks "AnyWire",
To enrich the lineup flexibility to integrate the various layers of automation network MITSUBISHI Programming Manual.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.
Real time transmission control data, to improve the production efficiency and the value of the equipment to provide support for the high-speed data communication module. Q172HCPU Programming Manual.
The high accuracy data that can be synchronized with the sequential scanning to the user program on the PC can be transmitted through the Ethernet.
Realize the previous communication method can not achieve the detailed control of ddata transmission,
Real time data analysis using user applications,
In order to provide support for improving production efficiency and equipment value Q172HCPU Manual.