1 channels.
Input (weighing sensor output): V/V 0.0~3.3m.
Output (resolution): 0~10000.
Conversion speed: 10ms.
18 point terminal.
Weighing sensor input module capable of directly connecting with all kinds of weighing sensor Q173DCPU PDF.
The weighing sensor can now be directly connected to a programmable controller system,
Without the need for an external connection to the signal converter, etc.
Q173DCPU
By ensuring the accuracy of the weighing sensor, stable data conversion speed,
To achieve a high precision measurement.
No external signal converter!
The weighing sensor input module is directly connected to the programmable controller, which can reduce the time and cost of the sensor!
Various types of weighing sensors can be connected with the magnetostrictive type, capacitive type, rotary instrument or strain gauge Q173DCPU PDF.
Can connect 6 wire system (combined with remote sensing technology and ratio method) or 4 wire system weighing sensor Q173DCPU PDF Q173DCPU Manual . Master station.
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 156kbps MITSUBISHI Programming Manual.
CC-Link/LT from the station does not need any parameter settings.
Only need to set up the transmission speed in the master module, you can use the remote I/O.
QJ61CL12 can be used as the main station of CC-Link/LT.MODBUS RTU/MODBUS ASCII Master slave station.
RS-232.
RS-422/485.
MODBUS interface module capable of connecting MODBUS compatible device such as temperature regulator, measuring device and so on MITSUBISHI Programming Manual.
Support MODBUS communication function, and can be compatible with the third party MODBUS to communicate from various station equipment.
Support MODBUS communication functions from the station, can communicate with the third party programmable controller MODBUS master device MITSUBISHI Programming Manual.
Through the linkage function, the mmaster can be connected to the CH1 side (RS-232),
And through the QJ71MB91 and connected to the CH2 side (RS-422/485) of a number of stations for communication Q173DCPU Programming Manual.
The RS-232 interface (1 credit on the 1 pass) MODBUS master device withh multiple MODBUS communication from the station equipment Q173DCPU Manual . (only QJ71MB91)
Master / slave station functions can be used simultaneously. (only QJ71MT91)