"2 axes, SSCNET connection type.
2 axis linear interpolation.
2 axis interpolation.
Control unit: mm, inch, degree, pulse.
Location data: 600 data / axis Q173DSCPU PDF.
40 pin connector.
Easy to achieve high speed, high precision positioning control.
Support for multiple types of positioning control,
Including 2 ~ 4 axis 2 axis linear interpolation, circular interpolation, speed control and speed / position control, path switching control, constant speed control etc
Q173DSCPU.
In addition, can use the "Configurator-QP GX" and other software,
Easy to set, monitor and debug.
Saving wiring through SSCNET cable connections while simultaneously,
The length of the total cable distance up to 30m Q173DSCPU PDF.
In addition, an absolute position system for determining the origin position is supported by the return data set operation of the origin.
No need for the near point block, such as wiring. "Output: 2 channels.
Input (resolution): 0~12000; -12000~12000; 0~12000; -16000~16000 Q173DSCPU PDF.
Output DC0~20mA; DC-12~12V.
Conversion speed: 10ms/1 channel.
18 point terminal station.
Isolation between channels.
The possibility of expanding control with intelligent function.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark MITSUBISHI Programming Manual.
Provide support for process control using a general purpose programmable controller.
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output MITSUBISHI Programming Manual.
Hardware and installation costs have been greatly reduced due to the need for an external isolation amplifier.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input module.
No external isolation amplifier required MITSUBISHI Programminng Manual Q173DSCPU Manual.
Without the use of inter channel isolation analog modules.
Using the inter channel isolation analog module. Input / output points: 4096 points.
You can use the CF card.
Version OS:VxWorks 5.4.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.
Easy connection through the hub CPU.
By using an Ethernet hub, programming tools and multiple CPU can be connected simultaneously.
Through the programming tool can be searched and displayed in the list has been connected to the CPU.
Therefore, even if the IP CPU address is unknown, just choose from this list, you can easily connect.
Seamless communication without network level constraints.
With the latest high-speed, large capacity IE CC-Link controller netwwork and IE CC-Link field network,
Corresponding to the increasing amount of information Q173DSCPU Programming Manual.
Together with previous MELSECNET/H, Ethernet and CC-Link,
These networks can be across the network type or level of differences, to achieve seeamless communication Q173DSCPU Manual.
Programmable logic controller on the network through the programming tool of the Ethernet connection,
Monitoring and programming.