Redundant CPU data tracking cable length of 1 meters.
Can only be used for MITSUBISHI Q series PLC redundancy CPU.Cable length 1.2 meters.
Extended substrate for connection Q173HCPU-T PDF. Input: 2 channels.
500/200/100/10kpps.
Counter input signal: DC5/12/24V.
External input: DC5/12/24V.
Uniform output: Transistor (drain type).
DC12/24V.
0.5A/ point.
2A common end.
40 pin connector. Relay output: 32
Q173HCPU-T
Rated current and voltage: DC24V/AC240V, 2A/1 point, 5A/1 public end, 8 point 1 Public end.
External wiring connections: 38 terminals (terminals sold separately).
Replacement model: AY13.Input and output points: 4096 points Q173HCPU-T PDF.
Input / output data points: 8192 points.
Program capacity: 124k.
Basic command processing speed (LD command) S:0.075.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of Q173HCPU-T PDF.
The photoelectric couplerr is composed of two luminous two extreme tubes and a photoelectric transistor Q173HCPU-T Manual.
Light emitting diode two: the input of a photo coupler and the change of electrical signal,
The light signal is generated by the light emitting diode, which is the same as the input signal MITSUBISHI Programming Manual .
The working process of the input interface circuit: when the switch is closed, the diode light,
The transistor is then guided to the internal circuit and input signal under the irradiation of the light MITSUBISHI Programming Manual .
When the switch is off, the diode does not emit light, and the transistor is not on the way. Internal circuit input signal.
It is through the input interface circuit to the external switch signal into PLC internal can accept the digital signal MITSUBISHI Programming Manual .
Photoelectric three levels: in the light of the light signal conduction, the degree of light signal and the intensity of the light signal.
The output signal has a linear relationship with the input signal in the linear operating region of the photoelectric coupler.
User program storage capacity: it is a meeasure of how much the user application can store the number of indicators Q173HCPU-T Programming Manual .
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General llogical operation instructions each account for 1 words Q173HCPU-T Manual. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.