High speed data communication module.
10BASE-T/100BASE-TX.
Real time transmission control data, to improve the production efficiency and the value of the equipment to provide support for the high-speed data communication module Q173NCCPU PDF.
The high accuracy data that can be synchronized with the sequential scanning to the user program on the PC can be transmitted through the Ethernet.
Realize the previous communication method can not achieve the detailed control of data transmission,
Real time data analysis using user applications,
In order to provide support for improving production efficiency and equipment value Q173NCCPU PDF
Q173NCCPU Input points: 16 points.
Input voltage and current: 8mA AC100-120V (AC100V; 60Hz) /7mA (AC100V; 50Hz).
Response time: 20ms.
16 points / a common end.
18 point spring clip connection terminal.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location Q1773NCCPU PDF Q173NCCPU Manual .
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields MITSUBISHI Programming Manual.
Can also be used in combination with the CPU module to achieve appropriate control.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password MITSUBISHI Programming Manual.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights MITSUBISHI Programming Manual.
Easy connection programming tool via ethernet.
Programming tools (Workss2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings Q173NCCPU Programming Manual. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method annd the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection Q173NCCPU Manual .