Input: 4 channels.
Platinum resistance (Pt10; JPt100).
Conversion speed: 40ms/1.
Channel 18 point terminal.
Platinum thermal resistance (Pt100, JPt100) Q20UDEHCPU PDF.
Nickel thermal resistance (Ni100).
Shedding detection function.
Conversion speed: 320ms/8 channel.
Inter channel isolation.
40 pin connector.
Most suitable for process control of isolated analog modules.
Temperature data can be collected by connecting thermocouple / thermal resistance
Q20UDEHCPU
Products can choose multi-channel (8 channel) input type and channel isolation type.
Customers can choose the most suitable model according to the intended use Q20UDEHCPU PDF.
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance Q20UDEHCPU PDF.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown.
Auto backup key data
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameters due to forgetting to replace the battery MITSUBISHI Programming Manual Q20UDEHCPU Manual.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and other planned downtime,
The data is lost due to battery depletion MITSUBISHI Programming Manual.
The next time the power is turned on, the backup data will be automatically restored. Input / output points: 4096 points.
You can use the CF card.
Version OS:VxWorks 5.4.
Simply insert the SD memory card, you can automatically record.
Simply insert the SD in the CPU to save the record setting file, you can automatically start recording MITSUBISHI Programming Manual.
Even when remote data collection is required,
After receiving a record setting file by mail and copy it to the SD memory card,
Can immediately start recording.
Automatically transfer the record file to the FTP server
Simply by recording the configuration tool to carry out a simple setup,
A data record file stored on the SD memory card can be sent to tthe FTP server Q20UDEHCPU Programming Manual.
Because the record server can handle multiple files, it can reduce the task of management and maintenance.
When a failure occurs, it can quickly respond to.
Simply extract the data associated with the problem, do noot have to spend a lot of time to filter a large number of diagnostic data,
So it can quickly determine the cause of the failure, and make the solution Q20UDEHCPU Manual.