Input and output points: 512 points.
Input / output data points: 8192 points.
Program capacity: 28k.
Basic command processing speed (LD command) S:0.2 Q20UDHCPU PDF.
PLC in the program execution stage: according to the order of the user program order to store the order of each instruction,
After the corresponding operation and processing, the result is written to the output status register,
The contents of the output status register are changed with the execution of the program
Q20UDHCPU
Output refresh phase: when all instructions are executed,
The output status register is sent to the output latch in the output refresh stage,
And through a certain way (relay, transistor or trransistor) output, drive the corresponding output equipment Q20UDHCPU PDF Q20UDHCPU Manual. 8 axes, open collector output type.
Control unit: pulse.
Location data: 10 data / axis.
Maximum pulse output: 200Kpps.
40 pin connector.
Ideal solution for simple multi axis positioning Q20UDHCPU PDF.
Perfect match with stepper motor control.
Plus deceleration smooth, speed change subtle.
To speed up the speed of positioning control to start processing.
Positioning module.
Open collector output.
Differential driver output.
Based on the use of open collector outputs and differential drive output type 2 types MITSUBISHI Programming Manual.
Differential driver output type positioning module can transmit high speed instruction pulse (up to 4Mpps) to the servo amplifier reliably,
Transmission distance of up to 10 meters, to achieve high speed and high precision control.
(the command pulse of the open collector positioning module is highest 200kpps MITSUBISHI Programming Manual. )
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc Q20UDHCPU Programming Manual. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance MITSUBISHI Progrramming Manual Q20UDHCPU Manual.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown.