RS-232 1 channel.
RS-422/485 1 channel.
Transmission speed: 2 channels.
Total 230.4kbps.
Corresponding Configurator-SC Version2 GX.
Serial communication module capable of collecting and changing data of programmable controller, monitoring and managing, measuring data collection and so on Q24DHCCPU-VG PDF.
Can achieve the highest speed of 230.4kbps, the maximum of 960 words (MC protocol communications) of the high speed and large capacity communications
Q24DHCCPU-VG
Can use MC protocol, through the external devices (PC, monitors, etc.) to implement the data read / write programmable controller.
By selecting a non sequential protocol and use sequential program for communication control, the programmable controller and the external device (barcode reader and measurement equipment),
Communication with local protocols using external devices Q24DHCCPU-VG PDF.
QJ71C24N (-R2) through the RS-232 serial communication,
Programming and monitoring of prrogrammable controllers using programming tools Q24DHCCPU-VG PDF Q24DHCCPU-VG Manual .
QJ71C24N (-R2) with the function of the modem corresponding to the public telephone line,
Can be used to initialize the modem, and the connection of the object device processing,
Communication with a remote device, a programming tool, a modem, and a public telephone line MITSUBISHI Programming Manual.
Using remote password,
Can be prevented by QJ71C24N (-R2) function of the modem Q series programmable controller for illegal access. 10BASE-T/100BASE-TX.
Ethernet interface module capable of selecting the most suitable system and object device.
Support 100BASE-TX, can speed up the transmission speed MITSUBISHI Programming Manual. (QJ71E71-100)
Data communication can be performed between programmable controller CPU using special instructions.
Can use the HTTP protocol, through the Web browser on the PC access to the soft element of the programmable controller.
PC (Web) on the use of the communication program library and sample screen can be obtained by download services MITSUBISHI Programming Manual.
Can connect a number of programming tools to improve the efficiency of debugging Q24DHCCPU-VG Programming Manual.
Make use of e-mail function, through the mail server to send e-mail (ASCII format) and attachments (binary, ASCII and CSV format).
The KeepAlive function can be used to perform the existeence of the object equipment inspection, and keep the connection in the open state Q24DHCCPU-VG Manual .
This can be used to ensure connectivity and to quickly find errors.