Three-phase 3 wire type.
Measuring circuit number: 4 circuits.
Measurement items: power consumption (consumption, regeneration), current, voltage, power, power factor, etc Q26UDVCPU PDF. .
Power measurement module product group capable of simply measuring various energy information.
With only one module can be used to measure and power consumption (consumption and regeneration), reactive power, current, voltage, power, power factor and frequency of all kinds of detailed information
Q26UDVCPU
No ladder program can continue to monitor the minimum and maximum values, can also perform 2 types of upper / lower limit alarm Q26UDVCPU PDF.
Only in the ON state can be used to measure the output of the output device.
Therefore, the amount of electricity and the quantity of electricity in the unit of the beat can be obtained during the operation of the equipment.
3 phase 3 wire products can be used to measure up to 4 circuits in one slot,
3 phhase 4 wire products can be used to measure up to 3 circuits,
So the electrical energy measurement can be carried out in a small space by the multi circuit products Q26UDVCPU PDF Q26UDVCPU Manual.
For example, a module can be used to measure other loads from the control panel trunk.
In addition, Works2 GX (version 1.90U and higher) can be used to easily set parameters MITSUBISHI Programming Manual . 8 channel.
Input: DC-10~10mA; 0~20mA.
Output (resolution): 0~4000; -4000~4000; 0~12000; -12000~12000; 0~16000; -16000~16000.
Conversion speed: 10ms/ channel.
40 pin connector.
Isolation between channels.
The possibility of expanding control with intelligent function MITSUBISHI Programming Manual .
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark.
Provide support for process control using a general purpose programmable controller.
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output MITSUBISHI Programming Manual .
Hardware and installation costs haave been greatly reduced due to the need for an external isolation amplifier Q26UDVCPU Programming Manual .
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input modulee Q26UDVCPU Manual.
No external isolation amplifier required.
Without the use of inter channel isolation analog modules.
Using the inter channel isolation analog module.