Input: 4 channels.
Platinum resistance (Pt100; JPt100; Ni100).
Conversion speed: 40ms/1 channel.
18 point terminal.
Isolation between channels.
Platinum thermal resistance (Pt100, JPt100) Q2ACPU PDF.
Nickel thermal resistance (Ni100).
Shedding detection function.
Conversion speed: 320ms/8 channel.
Inter channel isolation.
40 pin connector.
Most suitable for process control of isolated analog modules
Q2ACPU
Temperature data can be collected by connecting thermocouple / thermal resistance.
Products can choose multi-channel (8 channel) input type and channel isolation type.
Customers can choose the most suitable model according to the intended use Q2ACPU PDF.
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance Q2ACPU PDF.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown.
Auto backup key data
Save the program and parameter files automatically too the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameters due to forgetting to replace the battery MITSUBISHI PROGRAMMING MANUAL Q2ACPU Manual.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and other planned downtime,
The data is lost due to battery depletion MITSUBISHI PROGRAMMING MANUAL.
The next time the power is turned on, the backup data will be automatically restored. PCI bus.
Support Japanese, English OS.
GI optical cable.
Dual loop controller network (control station / common station).
I/O control in the first class of open field network module MITSUBISHI PROGRAMMING MANUAL.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information).
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmission) communication separately, so as to ensure the timeliness of.
Even if the information rreaches saturation, it will not affect the link scan time Q2ACPU PROGRAMMING MANUAL.
DB A20 AnyWire system uses a separate transmission mode,
Sensor networks to achieve high speed and high reliability.
The transmission distance of 50m/200m/1km/3km can be selectted Q2ACPU Manual.
1 modules can be up to 512 points of the input, 512 points of output (standard setting).
Even branch wiring, but also to detect transmission lines.