Input voltage range: AC100-120V.
Output voltage: DC5V.
Output power: 6A.
Simplified program debugging.
Can use the software with the implementation of the conditions of the test function, any step in the program,
Changes the value of the soft component to a user specified value Q2ACPU-S1 PDF.
In the past, when debugging the specific loop process, the need to add a set of soft components of the program,
At present, through the use of the function, no need to change the program, you can make a specific loop program segment execution action
Q2ACPU-S1
Therefore, do not need to change the program separately in order to debug, debugging operation is more simple Q2ACPU-S1 PDF.
Through the expansion of soft components, more convenient to create the program.
M soft components and B soft components can be expanded to 60K points, making the program easier to understand.
Auto backup key data.
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameters due to forgetting to replace the battery Q2ACPU-S1 PDF.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holidaay and other planned downtime,
The data is lost due to battery depletion MITSUBISHI Programming Manual Q2ACPU-S1 Manual.
The next time the power is turned on, the backup data will be automatically restored.5 slots; requires 1 AnS series PLC power modules;
Used to install large AnS series PLC module.
Base plate of AnS series PLC.
QA1S series PLC 5 slot main substrate MITSUBISHI Programming Manual.
AnS series of modules can be installed. PCI bus.
Support Japanese, English OS.
3C-2V/5C-2V coaxial cable.
Single bus controller network (control station / common station).
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1 MITSUBISHI Programming Manual. 2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings.
Only need to set up the transmission speed in the master module, you can use the remote I/O.
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able tto transmit large number of bits data (such as ON/OFF information) and word data (such as analog information) Q2ACPU-S1 Programming Manual.
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmmission) communication separately, so as to ensure the timeliness of Q2ACPU-S1 Manual.
Even if the information reaches saturation, it will not affect the link scan time.