Input points: 16 points.
Input voltage and current: 6mA DC24V.
Response time: 0/0.1/0.2/0.4/0.6/1ms.
16 point /1 a public side.
Common anode.
18 point terminal station QS0J71GF11-T2 PDF.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings. And there is no need to select the cable, the straight line and the cross line can be used
QS0J71GF11-T2
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection QS0J71GF11-T2 PDF.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields QS0J71GF11-T2 PDF.
Can also be used in combination with the CPU module to achieve appropriate control.
Continue to go beyond, to climb the peak of Q series MITSUBISHI Safety Application Guide.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users MITSUBISHI Safety Application Guide.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.Input points: 64 points.
Input voltage and current: 4mA DC24V.
Response time: 0.1/0.2/0.4/0.6/1ms.
32 point /1 a public side MITSUBISHI Safety Application Guide.
Common anode.
40 pin connector.
Eaasy connection programming tool via ethernet QS0J71GF11-T2 Manual.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields.
Can also be used in combination with the CPU module to achieve appropriate control.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password. QS0J71GF11-T2 Safety Application Guide.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorizeed access to unauthorized users QS0J71GF11-T2 Manual.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.