Name: Position Control Module.
Model: C200H-NC211.
Control method: Open-loop, automatic trapezoid acceleration/deceleration.
Control output sig-nals: Pulse-train outputs CJ2H-CPU64-EIP PDF.
Controlled axes: 2.Product name: E@@S type CPU Units with 30 I/O Points.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 18; Outputs, 12;
Output type: Relay.
Program capacity: 2K steps.
memory Data capacity: 2K words
CJ2H-CPU64-EIP
External powersupply(24 VDC): 0.30A.
Current consumption: 5 V, 0.17A; 24 V,0.07A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality CJ2H-CPU64-EIP PDF.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Product name: N@@-type CPU Units with 40 I/O Points.
Specifications: Power Supply, 24 VDC; Inputs, 24; Outputs, 16;
Output type: Transistor (sinking) CJ2H-CPU64-EIP PDF.
Program capacity: 8K steps.
memory DData capacity: 8K words CJ2H-CPU64-EIP Manual.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.31A; 24 V,0.02A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient OMRON PROGRAMMING MANUAL.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection OMRON PROGRAMMING MANUAL. Model: CPM2C-24EDTM. Units with 24 I/O points
2 MIL connectors.
Inputs: 16 inputs.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: sinking transistor.I/O capacity: 1, 024 pts (4, 096 max. with remote I/O).
Execution time: Basic: 0.125 µs min.Special: 0.5 µs min.
Specifications: 8 Kwords without clock OMRON PROGRAMMING MANUAL. Name: e-CON Connectors.
Specifications: Inputs; 8 inputs ; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced CJ2H-CPU64-EIP PROGRAMMING MANUAL.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CJ2H-CPU64-EIP Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.