Output method: Analog resolution: 1/6000.
Analog Inputs: 4.UM: 15.2K words.
DM: 6K words.
EM: 6K words.
Instruction processing time (basic instructions): 0 CJ2H-CPU65 PDF. 15 µ.s min.
No. of I/O points: 880 points.
Max. no.of con-necting Expansion I/O Racks: 2 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO
CJ2H-CPU65Name: CS1D CPU Unit for Single CPU Systems.
Specifications: Number of I/O points,
5,120 points (7 Racks);
Program capacity, 60 Ksteps;
Data Memory, 128 Kwords(DM: 32 Kwords,
EM: 32 Kwords×13 banks);
LD execution time, 0 CJ2H-CPU65 PDF. 02 μs;
Duplex CPUs, --;
Interrupt functions, OK.
Current consumption: 5V system, 0.82A;
26V system, --.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. Product name: N@@S1- type CPU Units with 60 I/O Points CJ2H-CPU65 PDF.
Specifications: Power Supply, DC24V; Inputs, 36; Outputs, 24;
Output type: Transistor (sourcing).
Program capacity: 8K steps.
memory Data capacity: 8K words.
Externall powersupply(24 VDC): -- CJ2H-CPU65 Manual.
Current consumption: 5 V, 0.31A; 24 V,0.02A.
Standards: CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient OMRON REFERENCE MANUAL.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection OMRON REFERENCE MANUAL. Model : C500-LK103.
PCF.Terminal Resistance Unit Mount to an I/O Expansion Unit CV500-TER01Supply voltage: 100 to 240 V AC, 50/60 Hz (wide range).
Operating voltage range: 85 to 265 V AC.
Output capacity: 5 V DC: 3.6 A(18 W).Unit type: CJ1 CPU Bus Units.
Product Name: Serial Communications nits OMRON REFERENCE MANUAL.
Specifications:Communications Interface,
1 RS-232C port and 1 RS-422A/485 port;
Communications functions,
The following functions can be,
selected for each port:
Protocol macro Host Link,
NT Links (1:N mode)Serial Gateway,
No-protocol Modbus-RTU Slave.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.38A; 224V,-- CJ2H-CPU65 REFERENCE MANUAL.
Standards: UC1, N, L, CE.
The Serial Communications Units That Enable,
High-speed Connections with External Devices.
Each Serial Communications Unit provides two,
serial communications ports: RS-232C and,
RS-422A/485,, and the serial communications,
mode can be set separately for each port from,
Protocol Macro, Host Link, NT Link,
Serial Gateway, and No-protocol CJ2H-CPU65 Manual.