CPU Unit: CP1L-L CPU Units with 20 Points.
Specifications: CPU type, Memory capacity: 5K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, AC power supply; Output method, Relay output;
Inputs, 12; Output, 8 CJ2M-CPU34 PDF.
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port
CJ2M-CPU34
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams CJ2M-CPU34 PDF. Model: C200H-MR433.
Description: RAM, 4K words, battery back-up.with clock (CPU21, CPU23 only).Name: High-speed Counter Module.
Model: C200H-CT021.
Number of axes: 2 axis/Unit.
Operating modes: 7.
High-speed Counter Unit
A High-speed Counter Unit counts input signals from incremental rotary encoders or other sources CJ2M-CPU34 PDF. CPU Unit: CP1H-XA CPU Units.
Specifications: CPU type, Memory capacity: 20K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Analog inputs: 4, Analog outputs: 2;
Power supply, AC power supply; Output method, Relay output;
Inputs, 24; Output, 16 OMRON PROGRAMMING MANUAL.
Standards: UC1, N, L, CE.
4 Axis Position Control and Comprehensive Programmable Controller.
The CP1H-X with pulse outputs for 4 axes.
The CP1H-Y with 1-MHz pulse I/O.
The CP1H-XA with pulse outputs for 4 axes and built-in analog I/O OMRON PROGRAMMING MANUAL. Model: CPM2C-TS101. 2 inputs for temperature resistance thermometers C500-OC I/O Unit Transistor Output 16 pts C500-OC221-E(3G2A5-OC221-E).
AC250/DC24V 2A.Model: C200H-OC221.
No. of points: 8 pts.
Specifications: 2A, 250VAC/24VDC(For resistive loads).Model: C200HS-ME16K.
Description: EEPROM, 16K words OMRON PRROGRAMMING MANUAL CJ2M-CPU34 Manual. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Analog Output Unit.
Output points : 4 inputs.
Signal range selection:
Set separately for each input.
Signal range: 4 to 20 mA, 1 to 5 V.
Conversion speed (resolution):
100ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and sppace compared,
with previous systems CJ2M-CPU34 PROGRAMMING MANUAL.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CJ2M-CPU34 Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.