CPU Unit: CP1L-EM CPU Units with 30 Points.
Specifications: CPU type, Memory capacity: 10K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Transistor output(sinking);
Inputs, 18; Output, 12 CP1H-X40DR-A PDF.
Standards: CE.
High Performing Programmable Controller with Embedded Ethernet
CP1H-X40DR-A
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams CP1H-X40DR-A PDF. Power supply: DC power supply.
Output method: Relay output.
Inputs points: 6 points.
Outputs points: 4 points.Name: MIL Connectors.
Specifications: Inputs;
32 inputs ; PNP; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet. CP1H-X40DR-A Manual.
Branching is easily made with CompoNet CP1H-X40DR-A PDF.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error OMRON REFERENCE MANUAL. Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit.
I/O points: 4 inputs ; 2 outputs.
Signal range selection:
Set separately for each input and output OMRON REFERENCE MANUAL.
Signal range, Resolution: 1 to 5 V,
0 to 5 V, 0 to 10 V, -10 to 10 V,
4 to 20 mA.
Resolution: 1/4,000 (Settable to 1/8,000).
Conversion period: 1 ms/point,
(Settable to 500 μs/point).
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F.S. Current: ±0.2% of F.S;
Voltage: ±0 OMRON REFERENCE MANUAL. 3% of F.S. Current: ±0.3% of F.S.
External connection: Removable terminal block.
External power supply: 24 VDC +10% -15%, 140mA max CP1H-X40DR-A REFERENCE MANUAL.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.58A; 24V, --.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Anaalog Input Units for converting analog input,
signals into binary data CP1H-X40DR-A Manual.
Analog Output Units for converting binary ,
data into analog output signals.