Product name: NA-type CPU Units with 20 I/O Points (Built-inanalog).
Specifications: Power Supply, 24 VDC; Inputs,
12(Built-inanalog inputs: 2; Outputs, 8(Built-inanalog outputs: 1;
Output type: Transistor (sourcing) CPM2C Series PDF.
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.23A; 24 V,0.09A.
Standards: UC1, N, L, CE
CPM2C Series
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection CPM2C Series PDF. Unit type: CJ1 Basic I/O Units.
Product name: DC Input Units.
Specifications: I/O points, 32 inputs;
Input voltage and current: 24 VDC, 4.1 mA;
Commons, 16 points, 1 common; External connection,
Fujitsu connector; No CPM2C Series PDF. of words allocated, 2 word.
Current consumption: 5V, 0.09A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Input,
Units for High Speed Input and,
Different Applications.
Receive ON/OFF signals from external,
devices into the PLC System to update,
I/O memory in the CPU Unit OMRON Safety Precautions.
New high-speed input models CJ1W-ID212 and,
CJ1W-ID233 are now available CPM2C Series Manual. These units can,
help to increase system throughput. UM: 15.2K words.
DM: 6K words.
EM: 6K words.
Instruction processing time (basic instructions): 0.15 µ.s min.
No OMRON Safety Precautions. of I/O points: 880 points.
Max. no.of con-necting Expansion I/O Racks: 2 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.Model: C200H-PS211.
Supply voltage: 24VDC.Unit classification: CJ1 Special I/O Units OMRON Safety Precautions.
Product name: Isolated type DC Input Units.
Input points: 2 inputs.
Signal range selection: DC voltage:
0 to 1.25 V, -1.25 to 1.25 V, 0 to 5 V,
1 to 5 V, -5 to 5 V, 0 to 10 V, -10 to 10 V,
±10 V selectable range DC current:
0 to 20 mA, 4 to 20 mA.
Conversion speed (resolution): Conversion,
speed: 10 ms/2 inputs, Resolution: 1/64,000.
Accuracy at ambient temperature of 25°C:
Accuracy: (±0.05% of F.S.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Currrent consumption: 5V, 0 CPM2C Series Safety Precautions. 18A; 24V, 0.09A.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four inpuut channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage) CPM2C Series Manual.
All inputs are isolated.