Name: Temperature Input Units.
Specifications: Platinum-resistance,
thermometer input; 4 inputs;
PT100 (-200 to 850°C),
PT100 (-200 to 2000°C).
Standards: CE, UC, UC1, N CS1D-CPU67S-IAP PDF.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system
CS1D-CPU67S-IAP
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error CS1D-CPU67S-IAP PDF. Unit classification: CJ1 CPU Bus Units.
Product name: Motion Control Unit with,
MECHA TROLINK-II interface.
Specifications: Control modes : Position,
speed, or torque control via MECHATROLINK-II,
Control axes : 32 axes max CS1D-CPU67S-IAP PDF. (30 physical axes,
2 virtua axes).
Internal programming language: Special motion contro
language
No. of unit numbers allocated: 1 CS1D-CPU67S-IAP Manual.
Current consumption: 5V, 0.60A; 24V, --.
Standards: UC1, CE.
Improve Equipment Design Efficiency,
and Shorten Tact Time OMRON PROGRAMMING MANUAL.
Control Servos for up to 16 axes in,
a motion network with one Position,
Control Unit that supports MECHATROLINK-II.
MECHATROLINK-II is a registered trademark,
of the MECHATROLINK Members Association. Model: CPM2A-30CDT-D. Power supply: DC power supply.
Output type: Transistor sinking OMRON PROGRAMMING MANUAL.
Inputs points: 18 points.
Outputs points: 12 points.Unit classification: CJ1 Special I/O Units.
Product name: Process Analog Input Units,
(Isolated-type Resistance Thermometer Input Units).
Input points: 4 inputs.
Signal range selection: Common inputs.
Signal range: Resistance thermometer: Pt100, JPt100 OMRON PROGRAMMING MANUAL.
Conversion speed (resolution): Conversion,
speed: 250 ms/4 inputs.
Accuracy at ambient temperature of 25°C:
Accuracy: (±0.3% of PV or ±0.8°C,
whichever is larger) ±1 digit max.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Curreent consumption: 5V, 0 CS1D-CPU67S-IAP PROGRAMMING MANUAL. 25A; 24V, --.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four inputt channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage) CS1D-CPU67S-IAP Manual.
All inputs are isolated.