LK166
Home >> Download >> OMRON >> Manual Download >> OMRON CS1W-DA041 Instruction Manual PDF

OMRON CS1W-DA041 Instruction Manual PDF

Brand: OMRON
Product model: CS1W-DA041
Name: analog i/o module
Sort: Instruction Manual
File language: English
File size: 0.05MB
Power supply: DC power supply.
Output method: Transistor output sink type.
Inputs points: 6 points.
Outputs points: 4 points.Product name: CS1 Expansion Backplanes CS1W-DA041 PDF.
Specifications: For both CS/C200H-series,
Units; 3 slots.
Mountable configuration units:
Basic I/O Units, CS-series Basic I/O Unit,
Yes; C200H series Basic I/O Unit, Yes;
C200H Group-2 High density I/O Unit, Yes.
Special I/O Units: CS-series Special I/O Unit,
Yes; C200H series Special I/O Unit, Yes CS1W-DA041
CPU Bus Units: CS-series CPU Bus Unit, Yes.
Current consumption: 5V system, 0.23A;
26 V system, --.
Standards: U, C, N, L, CE CS1W-DA041 PDF.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Name: Temperature Input Units CS1W-DA041 Manual.
Specifications: Thermocouple Input; 4 inputs;
Switchable between.
(R, S, K, J, T, E, B, N, L, U, W, PL2)
Standards: CE, UC, UC1, N .
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet CS1W-DA041 PDF.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site OMRON Instruction Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Name: Two-tier Screw Terminal Block.
Specifications: Inputs; 16 inputs; PNP.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet OMRON Instruction Manual.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reductionn CS1W-DA041 Instruction Manual.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site OMRON Instruction Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,,
content of the error CS1W-DA041 Manual. Power supply: DC power supply.
Output method: Transistor output source type.
Inputs points: 6 points.
Outputs points: 4 points.
Related products
OMRON
CS1W-MC221-V1
OMRON  CS1W-MC221-V1
Control method: Semiclosed loop with automati
OMRON
Controller Link Units
CS1W-CLK13
OMRON Controller Link Units CS1W-CLK13
Unit classifi cation: CS1 CPU Bus Unit. Prod
OMRON
High-speed Counter Units
CS1W-CT021
OMRON High-speed Counter Units CS1W-CT021
Unit type: CS1 Special I/O Units. Name: High
OMRON
High-speed Counter Units
CS1W-CT041
OMRON High-speed Counter Units CS1W-CT041
Unit type: CS1 Special I/O Units. Name: High