LK166
Home >> Download >> OMRON >> Manual Download >> OMRON D4B-2A16N INSTRUCTION sheet PDF

OMRON D4B-2A16N INSTRUCTION sheet PDF

Brand: OMRON
Product model: D4B-2A16N
Name: safety limit switch
Sort: INSTRUCTION sheet
File language: English
File size: 0.32MB
Ratings: Standard load; 5 A at 125 VAC.
Cable: VCTF cable *2.
Actuator: Sealed roller plunger.
Cable length : 5 m.
Compact Limit Switch That''s Also D4B-2A16N PDF.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material D4B-2A16N
Cable lengths of 3 and 5 m available on standard models D4B-2A16N PDF.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmatioon of operation D4B-2A16N Manual.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking D4B-2A16N PDF.
(Applicable only to standard models.)Ratings: 0.1 A.
Actuator: Hinge roller lever.
Terminals: Solder terminals.
Contact form: SPDT.
Sealed Miniature Basic.
Switch Conforms to IP67.
(Excluding the terminals on terminal models).
Use of epoxy resin assures stable sealing, making OMRON INSTRUCTION sheet.
this switch ideal for places subject to water spray.
or excessive dust.
V-series internal mechanism assures high.
precision and durability. The mounting is the,
same as of the V models.
Ideal for automobiles, agricultural machines,
large-scale home appliances, and industrial,
equipment, which require high environmental resistance OMRON INSTRUCTION sheet. Release key type: Special release key.
Indicator: Orange.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 2NC/1NO+3NC.
Conduit opening: G1/2.
Holding Force of 3,000 N OMRON INSTRUCTION sheet.
Two safety circuits aand two monitor contacts provide an,
array of monitoring patterns D4B-2A16N INSTRUCTION sheet.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas. D4B-2A16N Manual.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection.
Related products
OMRON
Safety Limit Switch
D4B-2117N
OMRON Safety Limit Switch D4B-2117N
Actuator: Adjustale rod lever. Conduit open
OMRON
Safety Limit Switch
D4B-2570N
OMRON Safety Limit Switch D4B-2570N
Actuator: Plunger. Conduit openings: G1/2 P
OMRON
Safety Limit Switch
D4B-4511N
OMRON Safety Limit Switch D4B-4511N
Actuator: Roller lever resin roller. Condu
OMRON
Safety Limit Switch
D4B-4111N
OMRON Safety Limit Switch D4B-4111N
Actuator: Roller lever resin roller. Condu