Ratings: 0.1 A at 30 VDC.
Cable: VCTF oil-resistant cable*.
Actuator: Sealed crossroller plunger.
Cable length : 3m.
Compact Limit Switch That''s Also D4B-4111N PDF.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material
D4B-4111N
Cable lengths of 3 and 5 m available on standard models D4B-4111N PDF.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking D4B-4111N PDF.
(Applicable only to standard models D4B-4111N Manual. ) Specifications: Outputs; PNP (+ common); 16 points.
I/O connections: M3 Screw terminals.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Allows I/O Expansion with Transistor Terminals OMRON INSTRUCTION sheet.
Wide variety of data, such as maintenance system data,
can be collected without affecting the productivity,
of the control system.
Valuable information can be collected,
and managed through the network, including information,
on the communications power supply OMRON INSTRUCTION sheet.
voltage levels, Unit wear and tear,
and equipment operating information.
Expansion via Expansion I/O Units.
With no communications baud rate settings,
required and detachable terminal blocks,
maintenance is easier. Actuator: Plunger.
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 3NC (Slow-action) OMRON INSTRUCTION sheet.
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact foorms D4B-4111N INSTRUCTION sheet.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used witth both standard loads and microloads D4B-4111N Manual.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC.