Actuator: Roller lever (resin lever, resin roller).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 2NC/1NO MBB (Slow-action).
Popular Safety Limit Switches D4BS-6AFS PDF.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement
D4BS-6AFS
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) D4BS-6AFS PDF.
Certified standards: UL, EN (TÜV), and CCC. Type: Standard.
Contact gap: 3 mm min.
Mounting: Panel mounting.
Contact form: DPST-NO+SPST-NC.
Door Interlock Power.
Switch with Minimum.
Contact gap of 3 mm.
Offers the minimum contact gap of 3 mm required D4BS-6AFS PDF.
for power switches as standard equipment D4BS-6AFS Manual.
Safety considerations include a double return spring,
and direct drive positive contact opening feature.
Pull-on lock model for easy maintenance is also available. Type: M8.
Actuator: Cone-shaped actuator.
Cable length: 3 m.
Detects Objects in Multiple Directions,
with High Sensitivity, Ideal for Robotics,
Slow-action switching mechanism used OMRON INSTRUCTION sheet.
Gold-plated contact with coil spring capable of switching,
micro current/voltage load while providing high contact reliability.
Inputs directly to microcomputers and programmable controllers OMRON INSTRUCTION sheet.
Three sizes (M10, M8, and M5) and three types of compact actuators.
Easy panel mounting. Type: 1-conduit.
Mounting direction: Front-side mounting.
Conduit size: G1/2.
1NC/1NO (Slow-action).
The Special Operation Key Activates a Direct.
Opening Mechanism to Open the Contacts.
and Shut Off Control Circuits when Protective OMRON INSTRUCTION sheet.
Doors Are Opened on Machine Tools or Other.
Equipment.
Conforms to EN (TÜV) standards corresponding to the CE marking.
Certified by UL and CSA standaards D4BS-6AFS INSTRUCTION sheet.
The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened. The EN-certified.
direct opening mechanism is indicated by on the Switch.
Malfunctions and false operationn prevented by special Operation Key D4BS-6AFS Manual.
Wide temperature range specifications: −40 to 80°C.
Degree of protection of the switch box: IP67 (EN60947-5-1).