Actuator: Roller lever (metal lever, metal roller).
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 1NC/1NO MBB(Slow-action).
Popular Safety Limit Switches D4JL-1QFA-C7-01 PDF.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement
D4JL-1QFA-C7-01
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) D4JL-1QFA-C7-01 PDF.
Certified standards: UL, EN (TÜV), and CCC. Optical System Achieves 1-μm Operating Position.
Repeatability in this 4-way Switch.
No-contact structure for high reliability.
Ceramic materials in measuring part for superior resistance to abrasion.
Two different output types (PNP and NPN) available D4JL-1QFA-C7-01 PDF. ,
Less abrasion and damage of mechanical contacts compared,
to switches with contacts, reducing fluctuation in the output.
More compact than previous OMRON models: 40% less mass,
15% liighter across the operating width D4JL-1QFA-C7-01 Manual. Actuator: Plunger OMRON INSTRUCTION sheet.
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 2NC/1NO MBB (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available OMRON INSTRUCTION sheet. )
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) OMRON INSTRUCTION sheet.
Certified standards: UL, EN (TÜV), and CCC. Receptacle box: G 1/2 Conduit.
Indicator: Without indicator.
Actuator: Roller lever *1, Sequential operation.
Approved standards: UL, CSA.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13).
Wide standard opperating temperature range:
-40°C to +100°C (standard type) D4JL-1QFA-C7-01 INSTRUCTION sheet.
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models aavailable for complex operations D4JL-1QFA-C7-01 Manual.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model.)