Actuator: Pin plunger.
Type: M16.
Operation Indicator: None.
Repeat accuracy: 3 µm max.
Operating force OF max: 2.45 N.
Cable lead outlet: Lead outlet, Connector; Length, 1 m D4N-2226 PDF.
Degree of protection: IP67.
High-precision Switch for Detecting Micron-unit,
Displacement.
Ideal for detecting and measuring wear of cutting,
tools or for original point of work.
Ceramic plungers on M5, M8, and slim models for,
superior abrasion resistance and resistance to,
temperature changes
D4N-2226
Direct input possible to microprocessors and,
programmable controllers.
A version with screw-type cable connector available,
for easy installation and maintenance D4N-2226 PDF. Type: Welding / wire type, with left column.
Drive rod: needle shaped button type.
Terminal specifications: with wire, the right side of the lead.
Contact specifications: 1a.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment D4N-2226 PDF.
No swing bars are also used for easy long stroke specifications (OT reference value: 1.4mm).
Without harmful substaances to the environment, the lead type has also been lead-free OMRON INSTRUCTION sheet D4N-2226 Manual. Actuator: Roller lever (resin lever, resin roller).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 2NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms OMRON INSTRUCTION sheet.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) OMRON INSTRUCTION sheet.
Certified standards: UL, EN (TÜV), and CCC. Release key type: Special release key.
Indicator: Green.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 3NC+2NC/1NO.
Conduit opening: M20.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns D4N-2226 INSTRUCTION sheet.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas. D4N-2226 Manual.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection.