Brand: OMRON
Product model: D4N-2B87
Name: safety limit switch
Sort: INSTRUCTION sheet
File language: English
File size: 0.61MB
Release Key Type: Standard (metal).
Wiring method: Connector.
Solenoid voltage/Indicator: 24VDC (without indicator).
Lock and release type: Solenoid lock Mechanical release D4N-2B87 PDF.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 4-contact Model,
Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank @.
Conduit size (See Note.): 1/2-14NPT D4N-2B87
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal D4N-2B87 PDF.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
D4N-2B87 PDF.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames.
The plastic material makes the Slide Key suitable,
for lightweight doors. Receptacle box: G 1/2 Conduit OMRON INSTRUCTION sheet.
Indicator: With LED indicator (DC).
Actuator: Roller lever *1, High-sensitivity.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13) OMRON INSTRUCTION sheet.
Wide standard operating temperature range:
-40°C to +100°C (standard type).
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break modelss available for complex operations D4N-2B87 Manual.
Approved by UL, CSA, and CCC (Chinese standard) OMRON INSTRUCTION sheet.
(Ask your OMRON representative for information on approved model.) Lock method: Mechanical lock.
Conduit size: M20.
Voltage for solenoid: 24 VDC.
Without indicator 2NC+ 1NC (Slow-action).
Release Protective Cover Locks Using.
Controller Signals or Pushbutton.
Switches after the Cutting Tool Stops.
Moving Due to Inertia.
A mechanical lock is applied automatically when the Operation.
Key is inserted. A high level of safety is achieved using a,
mechanism where the lock is only released when voltage is,
applied to the solenoid.
Conforms to EN (TÜV) standards corresponding to the CE marking.
Certified by UL, CSA and CCC standards.
The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened.
Direct opening mechanism that is EN-certified is indicated by,
on the Switch.
Auxiliary release key ensures easy maintenance and unlocks the,
door in the case of a power failure.
Tough aluminum die-cast body incorporating a switch box wiith,
degree of protection satisfying IP67, UL, and CSA TYPE6P, 13 D4N-2B87 INSTRUCTION sheet.
Equipped with a horizontal and vertical conduit opening.
Models incorporating easy-to-see indicators for monitoring and,
those using an adjustable Operation Key ffor a swinging door are available D4N-2B87 Manual.
The mounting direction of the head can be changed,
to allow the Operation Key to be inserted from four directions.
Related products
OMRON
Pull-reset Safety Limit Switch
D4N-2D62R
OMRON Pull-reset Safety Limit Switch D4N-2D62R
Actuator: One-way roller arm lever horizonta
OMRON
Safety Limit Switch
D4N-6162
OMRON Safety Limit Switch D4N-6162
Actuator: One-way roller arm lever horizonta
OMRON
Safety Limit Switch
D4N-8A31
OMRON Safety Limit Switch D4N-8A31
Actuator: Plunger. Conduit size: 2-conduit
OMRON
Safety Limit Switch
D4N-4C2H
OMRON Safety Limit Switch D4N-4C2H
Actuator: Adjustale roller lever, form lock