Release Key Type: Standard (metal).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (without indicator).
Lock and release type: Mechanical lock Solenoid release D4N-4132 PDF.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 4-contact Model,
Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank @.
Conduit size (See Note
D4N-4132): G1/2.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal D4N-4132 PDF.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
D4N-4132 PDF.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames.
The plastic material makes the Slide Key suitable,
for lightweight doors. Economical, High Utility Enclosed Switch OMRON INSTRUCTION sheet.
Enclosedd Switches with Built-in Basic Switches for High,
Repeatability and Durability of 10 Million Operations Minimum D4N-4132 Manual.
Panel mount versions have the same operating position as,
Z Basic Switch.
Suitable for applications demanding higher mechanical,
strength, dustproof and drip-proof properties than those,
on basic switches OMRON INSTRUCTION sheet.
Resin molded terminal versions are available.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.). Ratings: Standard load; 5 A at 125 VAC.
Cable: VCTF cable *2.
Actuator: Roller lever, high sensitivity OMRON INSTRUCTION sheet.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
CCable lengths of 3 and 5 m available on standard models D4N-4132 INSTRUCTION sheet.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
connfirmation of operation D4N-4132 Manual.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)