LK166
Home >> Download >> OMRON >> Manual Download >> OMRON D4N-4C72R INSTRUCTION sheet PDF

OMRON D4N-4C72R INSTRUCTION sheet PDF

Brand: OMRON
Product model: D4N-4C72R
Name: pull-reset safety limit switch
Sort: INSTRUCTION sheet
File language: English
File size: 0.54MB
Actuator: Roller lever (resin lever, resin roller).
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 2NC(Snap-action).
Popular Safety Limit Switches D4N-4C72R PDF.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement D4N-4C72R
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) D4N-4C72R PDF.
Certified standards: UL, EN (TÜV), and CCC. Actuator: Roller plunger.
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 2NC/1NO MBB (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms D4N-4C72R PDF.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying rreplacement D4N-4C72R Manual.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads OMRON INSTRUCTION sheet.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Release Key Type: Standard (metal).
Wiring method: Connector.
Solenoid voltage/Indicator: 24VDC (without indicator).
Lock and release type: Solenoid lock Mechanical release OMRON INSTRUCTION sheet.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 4-contact Model,
Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank @.
Conduit size (See Note.): 1/2-14NPT.
World''s smallest Class 6-contact Guard Lock OMRON INSTRUCTION sheet.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key inssertion point D4N-4C72R INSTRUCTION sheet.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lockk Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames D4N-4C72R Manual.
The plastic material makes the Slide Key suitable,
for lightweight doors.
Related products
OMRON
Safety Limit Switch
D4N-8D2H
OMRON Safety Limit Switch D4N-8D2H
Actuator: Adjustale roller lever, form lock
OMRON
Safety Limit Switch
D4N-9B72
OMRON Safety Limit Switch D4N-9B72
Actuator: One-way roller arm lever vertical
OMRON
Safety Limit Switch
D4N-622G
OMRON Safety Limit Switch D4N-622G
Actuator: Adjustale roller lever, form lock
OMRON
Safety Limit Switch
D4N-2D25
OMRON Safety Limit Switch D4N-2D25
Actuator: Roller lever metal lever, metal ro