Type: Welding / wire type, with left column.
Driving rod: swing lever type.
Terminal specifications: with wire, under the lead.
Contact specifications: 1b D4N-4E32 PDF.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used for easy long stroke specifications (OT reference value: 1
D4N-4E324mm).
Without harmful substances to the environment, the lead type has also been lead-free. Ratings: Standard load; 5 A at 250 VAC, 4 A at 30 VDC.
Cable: VCTF oil-resistant cable *1 D4N-4E32 PDF.
Actuator: Roller plunger.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection D4N-4E32 PDF.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphrragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material D4N-4E32 Manual.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables OMRON INSTRUCTION sheet.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models OMRON INSTRUCTION sheet. )Ratings: 0.1 A at 30 VDC.
Cable: VCTF oil-resistant cable*.
Actuator: Pin plunger.
Cable length : 5m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection OMRON INSTRUCTION sheet.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Caable lengths of 3 and 5 m available on standard models D4N-4E32 INSTRUCTION sheet.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
conffirmation of operation D4N-4E32 Manual.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)