Brand: OMRON
Product model: D4N-5C31R
Name: pull-reset safety limit switch
Sort: INSTRUCTION sheet
File language: English
File size: 0.54MB
Ratings: Standard load; 4 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Roller lever, high sensitivity.
Cable length : 3 m.
Compact Limit Switch That''s Also D4N-5C31R PDF.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection D4N-5C31R
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models D4N-5C31R PDF.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking D4N-5C31R PDF.
(Applicable only to standard models.)Release key type: Special release key.
Indicator: Green.
Lock and release types: Mechanical lock Solenoid reelease D4N-5C31R Manual.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 2NC/1NO+2NC/1NO OMRON INSTRUCTION sheet.
Conduit opening: G1/2.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas OMRON INSTRUCTION sheet.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection. Actuator: Roller plunger.
Conduit openings: M20.
1NC/1NO (Slow-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification OMRON INSTRUCTION sheet.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the levver D4N-5C31R INSTRUCTION sheet.
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NNEMA 3, 4, 4X, 6P, and 13) D4N-5C31R Manual.
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.
Related products
OMRON
Safety Limit Switch
D4N-6162
OMRON Safety Limit Switch D4N-6162
Actuator: One-way roller arm lever horizonta
OMRON
Safety Limit Switch
D4N-6E20
OMRON Safety Limit Switch D4N-6E20
Actuator: Roller lever resin lever, resin ro
OMRON
Safety Limit Switch
D4N-4A72
OMRON Safety Limit Switch D4N-4A72
Actuator: One-way roller arm lever vertical
OMRON
Safety Limit Switch
D4N-8232
OMRON Safety Limit Switch D4N-8232
Actuator: Roller plunger. Conduit size: 2-co