The drive rod: rod type Shibai leaf.
Contact specifications: 1a.
Rating: small load with 0.1A.
For the automobile, industrial vehicles, mechanical testing of the anti immersion type (in line with IP67)
Use M4 screw to achieve a little installation D4N-5D2HR PDF.
Using a strong fixed leaf swing rod which can adapt to the harsh environment.
Full consideration of environmental protection, the installation of the wire also lead to lead free
D4N-5D2HR Ratings: Standard load; 4 A at 30 VDC.
Cable: VCTF cable *2.
Actuator: Roller plunger.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed D4N-5D2HR PDF.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material D4N-5D2HR PDF.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation OMRON INSTRUCTION sheet.
(Set by default to light for non-operation.)
VCTF oil-rresistant cables with CE marking D4N-5D2HR Manual.
(Applicable only to standard models.)Actuator: Roller plunger.
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 2NC/1NO (Slow-action).
A Series of Pull-reset Models Now OMRON INSTRUCTION sheet.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability OMRON INSTRUCTION sheet.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Classification: Standard models.
Auxiliary monitoring output: Photocoupler outputs *1.
Cable length: 2 m.
Supports ISO 13849-1 (PLe/Safety Category 4).
Can be used on higher risk level applications,
by connecting to Safety Controllers.
Supports a wide range of applications in combination with,
Safety Controller G9SP or Non-contact Door Switch,
Controller G9SX-NS@.
Up to 30 units can be connected.
Ideal foor middle to large scale device applications D4N-5D2HR INSTRUCTION sheet.
Contributes to shortening the time it takes to find,
the cause of failure by the switch''s LED display patterns.
Photocoupler monitor output allows connection to,
a general-purpose PPLC (NPN type) D4N-5D2HR Manual.
Compatibility with the D40A allows standardization of machine design.
Compact Non-contact Door Switch can be mounted from both sides.