LK166
Home >> Download >> OMRON >> Manual Download >> OMRON D4N-6A62 INSTRUCTION sheet PDF

OMRON D4N-6A62 INSTRUCTION sheet PDF

Brand: OMRON
Product model: D4N-6A62
Name: safety limit switch
Sort: INSTRUCTION sheet
File language: English
File size: 0.61MB
Head material: Plastic*1.
Release key position: Bottom.
Release key type: Special release key(resin).
Solenoid voltage/indicator: Solenoid: 24 VDC, Orange LED: 10 to 115 VAC/VDC D4N-6A62 PDF.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch and,
lockmonitor switch contacts)(slow-action) Certified direct,
opening NC contact: 2NC+2NC D4N-6A62
Conduit opening: M20.
Best-selling Guard Lock Safety-door.
Switch Available in Several.
Compact, Multi-contact Models.
Selectable Operation Key insertion direction and,
adjustable mounting ensure installation flexibility D4N-6A62 PDF.
Built-in switches with multiple-contact construction are available.
Key holding force of 1,300 N minimum.
Can be used for either stanndard loads or microloads D4N-6A62 Manual.
Lineup includes models with a conduit size of M20.
IP67 degree of protection.
Variety of Metallic Heads Available D4N-6A62 PDF. The type of the drive lever: one way action roller rocker type (horizontal action).
Conduit size: single catheter type, M20.
Built in switch structure: slow motion (1NC/1NO).
Safety limit switch in accordance with global standard EN 50047.
The contact constitutes a complete variety, there is a single point of specification (1NC) and double contact specifications (1NC/1NO, 2NC) OMRON INSTRUCTION sheet.
Forced open action structure.
The slow moving contact structure is adopted to ensure that the contact distance is 4mm.
Elevator and escalator can be used. Measurement range: 5 mm.
Output specifications: B7A serial communications output (See note 2 OMRON INSTRUCTION sheet. ).
Actuator: Pin type.
Resolution: 1 µm.
Contact Displacement Sensor with Built-in.
Amplifier That Enables In-line Measurement.
of a Wide Range of Objects with a Low.
Operating Force.
Works with a low operating force (0.29 N) to detect a wide vari,
ety of objects iincluding glass, plastic, and rubber objects OMRON INSTRUCTION sheet D4N-6A62 INSTRUCTION sheet.
Models with digital output for B7A Units and models with 4- to,
20-mA linear output corresponding to the 0- to 5-mm measure,
ment range are available.
Models with ball-, flat-, or pin-type actuators are available for a,
wide variety of objects D4N-6A62 Manual.
The XS3 Sensor I/O Connector makes Sensor connections simple.
Related products
OMRON
Pull-reset Safety Limit Switch
D4N-8D62R
OMRON Pull-reset Safety Limit Switch D4N-8D62R
Actuator: One-way roller arm lever horizonta
OMRON
Pull-reset Safety Limit Switch
D4N-2A2GR
OMRON Pull-reset Safety Limit Switch D4N-2A2GR
Actuator: Adjustale roller lever, form lock
OMRON
Safety Limit Switch
D4N-6F2G
OMRON Safety Limit Switch D4N-6F2G
Actuator: Adjustale roller lever, form lock
OMRON
Safety Limit Switch
D4N-4FLE
OMRON Safety Limit Switch D4N-4FLE
Actuator: Fork lever lock left operation.