Actuator: Roller plunger.
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 3NC (Slow-action).
A Series of Pull-reset Models Now.
Available D4N-6E31 PDF.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability
D4N-6E31
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Type: Standard.
Contact gap: 3 mm min D4N-6E31 PDF.
Mounting: Panel mounting.
Contact form: DPST-NO.
Door Interlock Power.
Switch with Minimum.
Contact gap of 3 mm.
Offers the minimum contact gap of 3 mm required.
for power switches as standard equipment.
Safety considerations include a double return spring,
and direct drive positive contact opening feature D4N-6E31 PDF.
Pull-on lock model for easy maintenance is also available. Ratings: Standard load; 5 A at 250 VAC, 4 A at 30 VDC.
Cable: SJT(O) cable *3.
AActuator: Crossroller plunger D4N-6E31 Manual.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard) OMRON INSTRUCTION sheet.
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material OMRON INSTRUCTION sheet.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation OMRON INSTRUCTION sheet.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Type: Welding / wire type, with right column.
Driving rod: swing lever type.
Terminal specifications: with wire, the right side of the lead.
Contact specifiications: 1b D4N-6E31 INSTRUCTION sheet.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used ffor easy long stroke specifications (OT reference value: 1 D4N-6E31 Manual. 4mm).
Without harmful substances to the environment, the lead type has also been lead-free.