Ratings: Standard load; 0.1 A at 125 VAC, 0.1 A at 30 VDC.
Cable: VCTF cable *2.
Actuator: Sealed crossroller plunger.
Cable length : 5 m.
Compact Limit Switch That''s Also D4N-7A32R PDF.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection
D4N-7A32R
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models D4N-7A32R PDF.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking D4N-7A32R PDF.
((Applicable only to standard models D4N-7A32R Manual. )Type: Welding / wire type, with right column.
Driving rod: swing lever type.
Terminal specifications: with wire, under the lead.
Contact specifications: 1b.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment OMRON INSTRUCTION sheet.
No swing bars are also used for easy long stroke specifications (OT reference value: 1.4mm).
Without harmful substances to the environment, the lead type has also been lead-free OMRON INSTRUCTION sheet. Classification: Standard models.
Auxiliary outputs: Semiconductor outputs *1.
Cable length: 5 m.
Electronic Detection Mechanism for.
Better Stability in Non-contact Door.
Switch Operation. Actuator: Roller plunger.
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 2NC/1NO MBB (Slow-action) OMRON INSTRUCTION sheet.
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact foorms D4N-7A32R INSTRUCTION sheet.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used witth both standard loads and microloads D4N-7A32R Manual.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC.