Actuator: Adjustable roller lever, form lock (metal lever, rubber roller).
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 2NC/1NO (Slow-action) D4NH-9ABC PDF.
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement
D4NH-9ABC
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) D4NH-9ABC PDF.
Certified standards: UL, EN (TÜV), and CCC. Release Key Type: Standard (metal).
Wiring method: Connector.
Solenoid voltage/Indicator: 24VDC (without indicator).
Lock and release type: Mechanical lock Solenoid release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 4-contact Model,
Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank @ D4NH-9ABC PDF.
Conduit size (See Note.): 1/2-14NPT.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
OMRON INSTRUCTION sheet.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices D4NH-9ABC Manual.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point OMRON INSTRUCTION sheet.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames OMRON INSTRUCTION sheet.
The plastic material makes the Slide Key suitable,
for lightweight doors. Actuator: Roller lever (stainless steel roller).
Conduit openings: G1/2 (PF1/2).
1NC/1NO (Slow-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the levver D4NH-9ABC INSTRUCTION sheet.
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NNEMA 3, 4, 4X, 6P, and 13) D4NH-9ABC Manual.
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.