LK166
Home >> Download >> OMRON >> Manual Download >> OMRON D4NH-9EAS INSTRUCTION sheet PDF

OMRON D4NH-9EAS INSTRUCTION sheet PDF

Brand: OMRON
Product model: D4NH-9EAS
Name: safety-door hinge switch
Sort: INSTRUCTION sheet
File language: English
File size: 0.47MB
Ratings: Standard load; 0.1 A at 125 VAC, 0.1 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Plastic rod.
Cable length : 3 m.
Compact Limit Switch That''s Also D4NH-9EAS PDF.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection D4NH-9EAS
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models D4NH-9EAS PDF.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers D4NH-9EAS Manual.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking D4NH-9EAS PDF.
(Applicable only to standard models.)Release Key Type: Standard (metal).
Wiring method: Connector.
Solenoid voltage/Indicator: 24VDC (without indicator).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 4-contact Model,
Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank @ OMRON INSTRUCTION sheet.
Conduit size (See Note.): M20.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring OMRON INSTRUCTION sheet.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without deetaching the head OMRON INSTRUCTION sheet D4NH-9EAS INSTRUCTION sheet.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lockk Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames D4NH-9EAS Manual.
The plastic material makes the Slide Key suitable,
for lightweight doors.
Related products
OMRON
Safety-door Hinge Switch
D4NH-8DAS
OMRON Safety-door Hinge Switch D4NH-8DAS
Actuator: Shaft. Conduit size: 2-conduit M2
OMRON
Safety-door Hinge Switch
D4NH-4FBC
OMRON Safety-door Hinge Switch D4NH-4FBC
Actuator: Arm lever. Conduit size: 1-conduit
OMRON
Safety-door Hinge Switch
D4NH-8CAS
OMRON Safety-door Hinge Switch D4NH-8CAS
Actuator: Shaft. Conduit size: 2-conduit M2
OMRON
Safety-door Hinge Switch
D4NH-6BAS
OMRON Safety-door Hinge Switch D4NH-6BAS
Actuator: Shaft. Conduit size: 2-conduit G1