Ratings: Standard load; 0.1 A at 125 VAC, 0.1 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Crossroller plunger.
Cable length : 3 m.
Compact Limit Switch That''s Also D4NL-4AFA-B4 PDF.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection
D4NL-4AFA-B4
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models D4NL-4AFA-B4 PDF.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation D4NL-4AFA-B4 PDF. )
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Head material: Plastic*1.
Release key position: Bottom.
Release key type: Special release key(resin).
Solenoid voltage/indicator: Sollenoid: 24 VDC, Orange LED: 10 to 115 VAC/VDC D4NL-4AFA-B4 Manual.
Lock and release types: Solenoid lock Mechanical release OMRON INSTRUCTION sheet.
Contact configuration(door open/closed detection switch and,
lockmonitor switch contacts)(slow-action) Certified direct,
opening NC contact: 3NC+1NC/1NO.
Conduit opening: Pg13.5.
Best-selling Guard Lock Safety-door.
Switch Available in Several.
Compact, Multi-contact Models OMRON INSTRUCTION sheet.
Selectable Operation Key insertion direction and,
adjustable mounting ensure installation flexibility.
Built-in switches with multiple-contact construction are available.
Key holding force of 1,300 N minimum.
Can be used for either standard loads or microloads.
Lineup includes models with a conduit size of M20 OMRON INSTRUCTION sheet.
IP67 degree of protection.
Variety of Metallic Heads Available. Actuator: Pin plunger.
Type: M8.
Operation Indicator: None.
Repeat accuracy: 1 µm max.
Operating force OF max: 0.49 N.
Cable lead outlet: Lead outlet, Pre-wired; Length, 1 m.
Degree of protection: IP67.
High-precision Switch for Detecting Micron-unit,
Displacement.
Ideal for detecting and measuring wear of cutting,
tools or for original point of work D4NL-4AFA-B4 INSTRUCTION sheet.
Ceramic plungers on M5, M8, and slim models for,
superior abrasion resistance and resistance to,
temperature changes.
Direct input posssible to microprocessors and,
programmable controllers D4NL-4AFA-B4 Manual.
A version with screw-type cable connector available,
for easy installation and maintenance.