Release key type: Special release key.
Indicator: Green.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 2NC/1NO+2NC/1NO D4NL-4CFA-B4-NPT PDF.
Conduit opening: M20.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns.
Standard gold-clad contacts enable use with ordinary loads,
and microloads
D4NL-4CFA-B4-NPT
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas D4NL-4CFA-B4-NPT PDF.
IP67 degree of protection. Operation indicator: With operating indication; Standard load.
Ratings: 5 A at 125 VAC.
Actuator: Roller lever.
Cable length : 3m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard) D4NL-4CFA-B4-NPT PDF.
(Ask your OMRON representative for information on approved modeels D4NL-4CFA-B4-NPT Manual. )
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material OMRON INSTRUCTION sheet.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation OMRON INSTRUCTION sheet.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.) Specifications: Inputs, PNP (- common), 8 points.
I/O connections: Sensor I/O connector.
Rated internal circuit power supply voltage:
Supplied from the communications OMRON INSTRUCTION sheet. connector.
Rated I/O power supply voltage: 24 VDC.
Remote I/O Terminals with High.
Degree of Environmental Resistance.
(IP67) in Product Lineup Including.
Economical Input, Output, and Mixed I/O Models.
Common Smart Slaave functionality provides strong support for equipment,
operation status monitoring and effective maintenance D4NL-4CFA-B4-NPT INSTRUCTION sheet.
High degree of environmental resistance with dust-proof and drip-proof,
construction. (IP67)
Models with one cconnector for two outputs are available to make easier,
connection with hydraulic valve devices D4NL-4CFA-B4-NPT Manual.
(Models with 16 outputs and models with 16 mixed I/O)