Actuator: One-way roller arm lever (vertical).
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 2NC(Snap-action).
Popular Safety Limit Switches D4SL-N2HFG-D4 PDF.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement
D4SL-N2HFG-D4
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) D4SL-N2HFG-D4 PDF.
Certified standards: UL, EN (TÜV), and CCC. Release Key Type: Standard (metal).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (without indicator).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 4-contact Model,
Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank @ D4SL-N2HFG-D4 PDF D4SL-N2HFG-D4 Manual.
Conduit size (See Note.): G1/2.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring OMRON INSTRUCTION sheet.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point OMRON INSTRUCTION sheet.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames.
The plastic material makes the Slide Key suitable,
for lightweight doors OMRON INSTRUCTION sheet. Type: Welding / wire type, with right column.
Driving rod: swing lever type.
Terminal specifications: with wire, the right side of the lead.
Contact specificatioons: 1a D4SL-N2HFG-D4 INSTRUCTION sheet.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used ffor easy long stroke specifications (OT reference value: 1 D4SL-N2HFG-D4 Manual. 4mm).
Without harmful substances to the environment, the lead type has also been lead-free.