LK166
Home >> Download >> OMRON >> Manual Download >> OMRON D4SL-N2NDA-D4N INSTRUCTION sheet PDF

OMRON D4SL-N2NDA-D4N INSTRUCTION sheet PDF

Brand: OMRON
Product model: D4SL-N2NDA-D4N
Name: guard lock safety-door switch
Sort: INSTRUCTION sheet
File language: English
File size: 0.57MB
Actuator: Roller lever (stainless steel roller).
Conduit openings: G1/2 (PF1/2).
1NC/1NO (Slow-action).
Robust safety limit switch with metal housing D4SL-N2NDA-D4N PDF.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever D4SL-N2NDA-D4N
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion D4SL-N2NDA-D4N PDF.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NEMA 3, 4, 4X, 6P, and 13).
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.
Operation indicator: With operating indication; Standard load D4SL-N2NDA-D4N PDF.
Ratings: 4 A at 30 VDC.
Actuator: Adjustable roller lever.
Cable length : 5m.
Compact Limit Switch That''s AAlso D4SL-N2NDA-D4N Manual.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models OMRON INSTRUCTION sheet. )
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models OMRON INSTRUCTION sheet.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation OMRON INSTRUCTION sheet. )
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.) Actuator: Adjustable roller lever, form lock (metal lever, resin roller).
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 2NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NCC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC D4SL-N2NDA-D4N INSTRUCTION sheet.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability D4SL-N2NDA-D4N Manual.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC.